AromaSteam Operation and Installation Instructions
______________________________________________________________________________________________
Electrical Connection of
AromaSteam System
AromaSteam
Plug
240 VAC
Outlet
(grounded receptacle
required)
Request Cable
24 VAC
to steam generator
(see below)
AromaSteam Wiring
Schematic
AromaSteam Connections
CAUTION
!
This AromaSteam system is factory wired. If
the power cord of the Aroma Steam system is damaged it
must be replaced by the Sussman-Automatic service
department or similarly qualified personnel in order to
avoid an electric shock hazard. All electrical connections to
be made by a licensed, qualified electrician. Disconnect all
power to the steam generator before
making power connections.
IMPORTANT NOTE:
AromaSteam is for use with
iSteam
®
and iTempoPlus
®
controls only.
1. Disconnect all power to the Mr.Steam steambath
generator and remove the top cover.
2. Run the request cable from the AromaSteam System
through one of the knock outs in the side of the
steambath generator. Use a strain relief bushing
or grommet to prevent chafing.
3. Locate the two quick connect tabs labeled "AROMA"
on the PC board in the location show.
4. Connect the request cable to the terminals.
The terminals are not polarized.
6
Figure 5
Pressure Valve
Injector
Hose
Push Button
AromaSteam
Metering Pump
START-UP
Initial Priming of the Pump
1. Insure Mr.Steam scent container is full.
2. Insert the short injector hose onto the tip of the injector (see Fig. 5).
3. Unscrew the pressure end nut from the pump head and remove the
pressure hose from the pressure valve.
4. Insert the open end of the injection hose onto the pressure valve
(see Fig. 5).
5. Draw liquid from the injector slowly and evenly. Continue until the
injector is full of liquid.
6. If you have drawn up the injector completely and no liquid is in the
injector, remove the injector hose from the pressure valve.
7. Drain injector. Repeat steps until the injector is filled.
8. Save the oil injector as it will be needed when new oils are used.
Filling the Pressure Hose
1. Insure the AromaSteam System is primed and the scent container
is full.
2. Locate the Push-button at the rear of the metering pump
(see Fig. 6). Depress this push-button to start metering pump.
3. Continue to depress push-button until the pressure hose is filled
with liquid.
IMPORTANT NOTE:
Push button to be used only for initial filling
of the pressure hose, and after new oil bottles are installed.
Figure 6