mr.steam®Feel Good Inc.™Installation, Operation and Maintenance ManualSteambath Generator SystemsResidentialModels: MS90E – MS400E and MSSUPER1E – 6E
8K12””for servicingLIJHGFABCDEMGENERATOR DIAGRAMMS 90E- MS 400E MS Super 1E-3E_______________________________________A5 (127) 71⁄4 (184)B81⁄8 (206) 97
TransformerLiquid LevelControl BoardWater FeedSolenoidWater FeedLiquidLevel ProbeAutoFlush®Plug andPlay Connection(see page 14)FusesContactorPower Blo
FACTO RYWIRIN GFIELDWIRIN GLE G E N D(All Diagrams)CONTACTORHEATING ELEMENTTO PROBECONTROL BOARDAutoFlushSteamGenie oriGenie(optional)iSteam, iTempoor
INSTALLATION INSTRUCTIONSFOR MODELS: MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E1.Install each unit as in a single installation. Install the two generato
INITIAL START-UP AND CHECKOUT1. Turn on control. Follow specific instructions provided with controls.2. Steam will begin to appear in approximately 5
mr.steam®Installation, Operation & Maintenance Manual__________________________________________________________________________I N S T A L L E R13
I N S T A L L E R14OPTIONAL AUTOFLUSH®Box ContentsAutoFlush Valve with CordInstallation Instructions.OPERATIONThe optional AutoFlush System feature au
I N S T A L L E R15OPTIONAL DRIP PANMr. Steam strongly recommends the use of a drippan in the unlikely event of a plumbing leak.Locate the drip pan on
TransformerLiquid LevelControl BoardWater FeedSolenoidWater InletSafety ValveAutoFlushValve(optional)Stainless Steel TankHeating ElementExpress Steamh
REPLACEMENT PARTS LIST__________________________________________________________________________________________Part No. Description Generator________
mr.steam®Sussman-Automatic Corporation®[email protected] www.mrsteam.com43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM FAX: 718 472
CONTROL ROUGH INRefer to Installation Instructions for the specific controlIMPORTANT NOTE: The control cable should be run in adedicated 1” conduit to
READ ME FIRST!As you follow theseinstructions, you will notice warningand caution symbols. This blockedinformation is important for the safeand effici
CARE TIPS FOR ALL CONTROLS ANDSTEAMHEADS1. Use only mild soap and water on a soft cloth to cleanthe control and steamhead.2. DO NOT use abrasive clean
21mr.steam®Installation, Operation & Maintenance Manual__________________________________________________________________________H O M E O W N E R
mr.steam®Feel Good Inc.™www.mrsteam.commr.steam®Sussman-Automatic Corporation®[email protected] 34th Street, Long Island City, N
iTEMPO™ & iTEMPOPLUS™ CONTROLSInstallation, Operation & Maintenance Manual mr.steam® Feel Good Inc.www.mrsteam.com
HYPERTHERMIA occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The sympto
mr.steam® Installation & Operating Instructions______________________________________________________________3READ ME FIRST! As you follow thes
mr.steam® Installation & Operating Instructions______________________________________________________________4BEFORE INSTALLINGCarefully inspect
mr.steam® Installation & Operating Instructions______________________________________________________________521/2”41/2”1/4”3/8”3/4”1”5”5”33/4”1
RESIDENTIAL STEAMBATH GENERATOR SYSTEMSINSTALLATION, OPERATION & MAINTENANCE MANUALMODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E,MS-SUPER
mr.steam® Installation & Operating Instructions______________________________________________________________6DIAGRAM 2Installation Instructions
mr.steam® Installation & Operating Instructions______________________________________________________________7NOTE: The connector is keyed with
mr.steam® Installation & Operating Instructions______________________________________________________________8DIAGRAM 6Drawings for Illustrative
mr.steam® Installation & Operating Instructions______________________________________________________________9Drawings for Illustrative Purposes
mr.steam® Installation & Operating Instructions______________________________________________________________10Mr.Steam Steam Generator(shown wi
mr.steam® Installation & Operating Instructions______________________________________________________________115. Route the end of the probe cab
mr.steam® Installation & Operating Instructions______________________________________________________________12The iTempo Control features progr
mr.steam® Installation & Operating Instructions______________________________________________________________13DisplayUp KeyPause KeyDown KeyON/
mr.steam® Installation & Operating Instructions______________________________________________________________14mr.steamtemparoma chromatimemr
mr.steam® Installation & Operating Instructions______________________________________________________________15Drawings for Illustrative Purpose
2Materials of construction, room size and special design features suchas large glass areas, all affectthe steam generator model selection.1.Measure le
mr.steam® Installation & Operating Instructions______________________________________________________________16mr.steamaroma chromatimemr.ste
mr.steam® Installation & Operating Instructions______________________________________________________________17mr.steamchromatimetemparomamr.ste
mr.steam® Installation & Operating Instructions______________________________________________________________18Care Tips for all Controls and St
mr.steam® Installation & Operating Instructions______________________________________________________________19 te mpl ate for contro l i nstal
Products, information and specifications are subject to change without notice. For more information call Sales & Support at:1.800.76.STEAM (East Co
AutoFlush CordAutoFlush Valve3 Pin Connector for AutoFlushAutoFlushCordConnectorDrain Valve(shown in the correct open position)DO NOT REMOVE THIS DRAI
INSTALLING AUTOFLUSH ON OLDER MODELGENERATORS SN:899,999 and below1. Remove the connector from the "C" location inthe jacket. Cut off the co
I N S T A L L E R3If acrylic, fiberglass or other non-heat resistant mate-rials are used as part of the steam room enclosure. Consult with thematerial
LOCATING THE STEAM GENERATORSelect a location as near as practical to the steam room.Typical locations include: closet, vanity cabinet, heated attic o
TYPICAL INSTALLATION INSTRUCTIONSFOR MODELS MS SUPER 4E, 5E & 6E(shown with optional AutoFlush)1. Install each steam generator as in a single inst
INSTALLATIONPLUMBINGAll plumbing shall be performed by a qualified licensed plumber andin accordance with applicable National and local codes.1. Use u
SteamSupply PipeEnd of pipe to be recessed1/4"(without Acrylic Shield)1/8" (with Acrylic Shield)1/8" minimum clearance requiredwhen Acr