Mr. Steam 90C1ATSQPC Installation Guide Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Water Feed
Liquid
Level Probe
AutoFlush
®
Plug and
Play Connection
(see page 14)
Fuses
Contactor
Power Block
Power Supply
Knock-Out
Steam
Outlet
Field
Wiring
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Steam Outlet
Liquid
Level Probe
AutoFlush
®
Plug and
Play Connection
(see page 14)
Contactor
Power Supply
Knock-Out
Field
Wiring
Water Feed
FIELD POWER WIRING
1. TO AVOID EQUIPMENT DAMAGE
DO NOT CONNECT POWER SUPPLY
DIRECTLY TO ELEMENTS!!!
2. L1, L2, Ground to be field wired
3. Super 1E 240/1 models
are not supplied with internal fusing.
4. All Drawings are for illustrative
purposes only. Consult with qualified
licensed electrician for electrical
installation.
Models MS 90E–MS 400E
(single phase wiring shown)
Models MS Super 1E-6E
(single phase wiring shown)
ELECTRICAL
All electrical wiring to be installed by
a qualified licensed electrician in accordance with
National Electrical Code and local electrical code.
POWER WIRING
See “Field Power Wiring” Diagrams (below)
1. Check power voltage. Use 240V rated unit when supply
is greater than 208V. (Most homes have 240V, 1PH
service). Use 208V rated unit for 208V power.
2. Use minimum 90˚ C/300V rated insulated copper
conductors only, sized in accordance with National
Electrical Code and local electrical code for the current
in Ampere Chart. If allowed by codes, NM cable may
require a larger wire size than as listed on the chart.
3. Connect suitably sized equipment grounding wire to
ground terminal provided.
4. Install a separate circuit breaker between supply and
unit. Provide a power supply disconnect within sight
of the steam generator or one that is capable of being
locked in the open position.
5.
For single phase units, use two-wire supply source and
equipment grounding wire. Neutral (white) wire is not
required.
EL ECTRI CAL CH ART
________________________________________________________________________________________________________
V
ol Max Room Wire Size Wire Size
Model No.
(Cu. Ft.*)
KW
Volts
Phase Amps
(
AWG)for 40˚ C (AWG) for 45˚ C
Ambient Ambient
________________________________________________________________________________________________________
208 1 24 10 8
MS-90E 100 5.0 3 14 12 12
240 1 21 10 10
3 12 12 12
_
_______________________________________________________________________________________________________
208 1 29 88
MS-150E 150 6.0 3 17 10 10
240 1 25 88
3 14 12 12
________________________________________________________________________________________________________
208 1 36 88
MS-225E 225 7.5 3 21 10 10
240 1 32 88
3 18 10 10
________________________________________________________________________________________________________
208 1 44 8 6
MS-400E 360 9.0 3 25 88
240 1 38 88
3 22 10 10
_
_______________________________________________________________________________________________________
208 1 49 66
MS-Super 475 10.0 3 28 88
1E 240 1 42 86
3 24 88
________________________________________________________________________________________________________
208 1 58 64
MS-Super 575 12.0 3 34 88
2E 240 1 50 66
3 29 88
_
_______________________________________________________________________________________________________
208 1 73 43
MS-Super 675 15.0 3 42 86
3E 240 1 63 44
3 36 88
________________________________________________________________________________________________________
*See page 2 for room sizing.
All specifications shown are for 208V and 240V Consult factory for other voltage specifications.
9
PROVIDE A POWER SUPPLY DISCONNECT WITHIN SIGHT OF THE STEAM GENERATOR OR ONE
THAT IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION AS REQUIRED BY CODE.
I N S T A L L E R
mr
.
steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
WARNING
!
WARNING
!
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 45 46

Comments to this Manuals